1.  Sensorial examination – odour test

Sample was kept at ambient temperature (20-28 o C) and relativehumidity (40 – 80%) for 20 hours. Odour was tested with 5 panelists bsmelling immediately after opening 

the vessel.

Assessment – intensity scale

0 = no perceptible odour

1 = odour just perceptible

2 = slight odour

3 = distinct odour

2 Migration test for plastic material

A defined surface of the test item is put into the migration solution (water, acetic acid, ethanol,

 oil) for a defined timeat a defined temperature.

The migrated material is either determined as -loss of weight of the items or as -Dry residue 

of the migration solution

3 For metal container

The metal is dissolved by acid dissolution. The % of component are determined to decide 

whether the metal material can be used to come into contact with foodstuffs.

A defined surface of the test item is put into the migration 

solution (water, acetic acid or ethanol ) for a defined time at a defined temperature. The 

heavy metal release was determined by ICP

4.  General test condition:

Conditions of contact in 

worse foreseeable use

Test Conditions 

Conditions of contact in 

worse foreseeable use 

Test Conditions 

Contact time 

Test time 

Contact temperature 

Test temperature 

5 min < t <0.5 hrs 

0.5 hrs 

T < 5oC 

5oC 

0.5hrs < t < 1 hr 

1 hr 

5oC < T< 20oC 

20oC 

 1 hr < t < 2 hrs   2 hrs   20oC < T < 40oC   40oC 
 2 hrs < t < 4 hrs   4 hrs  40oC < T < 70oC   70oC 

4 hrs < t < 24 hrs 

 24 hrs   70oC < T < 100oC   100oC or reflux temperature 
 t > 24 hrs 

10 days 

 100oC < T < 121oC   121oC 
     121oC < T < 130oC 

130oC 

     130oC < T < 150oC 

150oC 

     T > 150oC 

175oC 